HK 90S4 B5 2-4 IE3

E-Motor 230/400V 1,1kW 1400U B5 IE3
P 50 Hz
1,1 kW
n 50 Hz
1.440 r/min
P 60 Hz
1,3 kW
Download PDF
Register now to get access to our online shop

Register now and access our complete product range and many exclusive services.

Product details for

HK 90S4 B5 2-4 IE3

P 50 Hz
1,1 kW
n 50 Hz
1.440 r/min
P 60 Hz
1,3 kW
n 60 Hz
1.740 r/min
LF 50 Hz
0,79
Faktor IA/IN
6,5
η (IE3) %
84
H1
130 mm
B
300 mm
C
245 mm
I 50 Hz
4,17 A
Ø D Welle
24 mm
Ø E
130 mm
Ø F
200 mm
All characteristics

Characteristics

Schutzart
  • IP 55 
Umgebungstemperatur
  • -20 °C bis +40 °C 
Werkstoff
  • Gehäuse: Aluminium 
Ausführung
  • Bauform B5 
  • ohne Füße 
Zolltarifnummer
  • 85015220 
All characteristics

Product description

Notes
Achtung! Maß »B« kann je nach Ausführung geringfügig länger ausfallen.
Description
Eigengekühlte Käfigläufer-Energiesparmotoren
High Efficiency IE3 - IEC60034-30:2009
Bemessungsspannung 230/400 V 50 Hz, 460 V 60 Hz
4-polig
Spannungstoleranz ±5 %

Product variants

5 Results
Show dimensional drawing
Identifier
P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN

Column selection

P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
LF 50 Hz
Factor IA / IN
η (IE3) %
H1 (mm)
B (mm)
C (mm)
I 50 Hz (A)
Ø D shaft (mm)
Ø E (mm)
Ø F (mm)
P 60 Hz = Nennleistung bei 400 V/60 Hz
n 50 Hz = Nenndrehzahl bei 400 V/50 Hz
n 60 Hz = Nenndrehzahl bei 400 V/60 Hz
I 50 Hz = Nennstrom bei 400 V/50 Hz
LF 50 Hz = Leistungsfaktor cos phi bei 50 Hz
P 50 Hz = Nennleistung bei 400 V/50 Hz
η (IE3) = Wirkungsgrad nach IE3 in % (bei Volllast)
Faktor IA/IN = Anlaufstrom IA / Nennstrom IN