PR 06-1 V2

Edelstahlrohr N 006,00x01,00 1.4541

Edelstahlrohr N 006,00x01,00 1.4541

Produktdetails zu

PR 06-1 V2

Ø d1
6 mm
S
1 mm
Belastungsfall I
379 bar
Belastungsfall III
272 bar
Ø d2
4 mm
AD-Toleranz +/-
0,08 mm
ID-Toleranz +/-
0,15 mm
Alle Eigenschaften

Eigenschaften

Ausführung
  • metrisch 
Bauart
  • Präzisionsstahlrohr, nahtlos (kalt gezogen), metrisch 
Materialzustand
  • CFA = blankgeglüht (geglüht, metallisch blank) 
Norm
  • DIN EN 10216-5 
Werkstoff
  • Edelstahl X6CrNiTi18-10 (1.4541 / AISI 321) 
Rohrlänge
  • 5 bis 7 Meter* 
Zolltarifnummer
  • 73044100 
Alle Eigenschaften

Produktbeschreibung

Hinweise
Le indicazioni della pressione riportate si riferiscono a un tubo diritto.
Per i tubi curvati si devono calcolare gli spessori corrispondenti delle pareti analogamente alla DIN EN 13480-4.
*Stainless steel tubes are supplied in manufactured lengths according to EN 10216-5. In terms of production, these are usually 6 meters (+/- 1m). Order quantities are rounded to the nearest possible total length, without cutting.
Beschreibung
The stainless steel pipes made of materials 1.4301 / AISI 304 (V1), 1.4541 / AISI 321 (V2) and 1.4571 / AISI 316Ti (V4) are supplied in CFA condition (bright annealed) as standard. This condition offers very good bendability and is the established standard in the hydraulics sector, particularly for the installation of pipelines.
Our stainless‑steel tubes are tested according to DIN EN 10216‑5. The dimensional tolerances (Ø, wall thickness, ovality) are restricted in accordance with DIN EN 10305‑1 ranging from 4 to 42 mm in outer diameter (Ød1). Larger dimensions are classified according to EN ISO 1127 D3/T.
Zusatzinformationen
Calcolo analogo alla DIN 2413
Specific load I: static (up to 120 °C)
Load case III: dynamic (up to 120 °C) stress range = P bar
Strength parameter: K 222 [N/mm²]
Safety coefficient: S 1.5
Fatigue strength: σSch/D 225 [N/mm²]
Tolerances (Ø, wall thickness, ovality) in accordance with DIN EN 10305-1
Elastic strength to DIN DIN 10216-5 Rp 1.0 to 50°C
Il valore della resistenza di soglia è stato ridotto in relazione al valore nominale della resistenza di 1.4571.
Bestellhinweis
Other delivery conditions, such as CFD, are available on request and must be specified separately.

Produktvarianten

63 Ergebnisse
Maßzeichnung anzeigen
Bezeichnung
Ø d1 (mm)
S (mm)
Caso di carico I : (bar)
Caso di carico III : (bar)

Zeigt 10 von 63 an

Spaltenauswahl

Ø d1 (mm)
S (mm)
Caso di carico I : (bar)
Caso di carico III : (bar)
Ø d2 (mm)
Tolleranza DE +/- (mm)
Tolleranza DI +/- (mm)