What are you looking for?

Enter search term

We are sorry!

Unfortunately no results were found.

Christmas / New Year shipping times
Our central warehouses will be closed from 23.12.2024 to 01.01.2025. Incoming orders will not be shipped during this period. If necessary, you are welcome to use our branch network during this time. Customer service will be available as usual.

Please note that our branches may have different opening hours during the holidays. For up-to-date information, we recommend calling ahead or checking the current opening times on Google Maps. Due to technical reasons, we are currently unable to update the opening hours on our website. Link to branch search on Google Maps

Login

Are you a new customer?

Register and get many benefits:

Checking the product availability
Fast reordering & order history
Personal product recommendation
Payment by invoice

Help & Contact

Your direct line to us

If you have any questions about the online store or our products, you can call our customer service at:

08:00 AM -12:00 AM 01:00 PM - 05:00 PM

Or use our FAQ

There you get answers to the most frequently asked questions.

Helping people help themselves
FAQs

HK V2 190 A600

Load lowering valve sa. IGR3/8" 350bar
Thread
G 3/8″ -19 
Q max.
40 l/min
Level control ratio
1:4 
Download PDF

Please choose a variant

Show table of articles
Register now to get access to our online shop

Register now and access our complete product range and many exclusive services.

Product details for

HK V2 190 A600

Thread
G 3/8″ -19
Q max.
40 l/min
Level control ratio
1:4
H
60 mm
L
100 mm
L1
148 mm
L2
30 mm
L3
60 mm
S
30 mm
All characteristics

Characteristics

Max. working pressure
  • max. 350 bar 
Design
  • single-acting 
Material
  • housing: galvanised steel 
  • internal parts made of steel 
Customs tariff number
  • 84812010 

Product description

Notes
When using these valve with a plunger cylinder, an additional pressure relief valve must be installed in the V1 line that has to be matched to the load pressure of the cylinder. This pressure relief valve must discharge to the tank.
These rate-of-drop valves must be set according to the application.
Set pressure = max. load pressure x 1.3

Product variants

2 Results
Show dimensional drawing
Identifier
Thread
Q max. (l/min)
Level control ratio
H (mm)
Price / items

Column selection

Thread
Q max. (l/min)
Level control ratio
H (mm)
L (mm)
L1 (mm)
L2 (mm)
L3 (mm)
S (mm)