Tipo
4/2
Bobina magnetica
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
Copertura
positivo (chiuso)
Seleziona una versione
Articolo
HK DHE 0610 X 00DC
HK DHE 0611 X 00DC
HK DHE 0613 X 00DC
HK DHE 0614 X 00DC
HK DHE 0630 2 X 00DC
HK DHE 0631 2A X 00DC
HK DHE 0631 2 X 00DC
HK DHE 0632 2 X 00DC
HK DHE 0710 X 00DC
HK DHE 0710 9 X 00DC
HK DHE 0711 X 00DC
HK DHE 0713 X 00DC
HK DHE 0714 X 00DC
HK DHE 0714 8 X 00DC
HK DHE 0714 9 X 00DC
HK DHE 0716 X 00DC
HK DHE 0717 X 00DC
HK DHE 0718 X 00DC
HK DHE 0719 1 X 00DC
HK DHE 0751 2 X 00DC
HK DHE 0711 P X 00DC
HK DHE 0713 P X 00DC
Registrati subito per accedere al nostro shop online.
Register now and access our complete product range and many exclusive services.
Dettagli del prodotto su
HK DHE 0611 X 00DC
Tipo
4/2
Bobina magnetica
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
Copertura
positivo (chiuso)
Tipo di pistone
1 [PB/AT]-[A/B/P/T]
Esecuzione
Ritorno molla
Tutte le caratteristiche
Caratteristiche
Pressione d'esercizio
- P, A, B: max. 350 bar / T: max. 210 bar
Esecuzione
- valvola a 4/2 vie o valvola a 4/3 vie
- valvola a 3 camere
- con azionamento manuale d'emergenza
- per bobine a corrente continua
Attacco
- ISO/Cetop 03 NG 6
Portata
- max. 80 l/min (si vedano le curve caratteristiche)
Elemento di fissaggio
- 4 pz. vite a testa esagonale interna M 5 x 30 12.9
- screw set HK M5 30 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required.
Customs tariff number
- 84812010
Tutte le caratteristiche
Descrizione del prodotto
Avvertenze
Descrizione
Note per l'ordine
Volume di consegna
Varianti dei prodotti
22 Risultati
Ricerca
Visualizza disegno quotato
Denominazione
Prezzo / Pezzo
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
negativo (aperto)
0 [PB/AT]-[ABPT]
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
positivo (chiuso)
1 [PB/AT]-[A/B/P/T]
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
positivo (chiuso)
3 [PB/AT]-[ABT/P]
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
negativo (aperto)
4 [PA/BT]-[A/B/PT]
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
negativo (aperto)
0/2 [PB/AT]-[PA/BT]
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
positivo (chiuso)
1/2 [PB/AT]-[PA/BT]
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
positivo (chiuso)
1/2 [PB/AT]-[PA/BT]
4/2
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
positivo (chiuso)
2/2 [PB/A/T]-[PA/B/T]
4/3
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
negativo (aperto)
0 [PB/AT]-[ABPT]-[PA/BT]
4/3
HK SP COE 12DC
HK SP COE 24 DC
HK SP COE 28DC
HK SP COE K 12DC
HK SP COE K 24DC
HK SP COE 230RC
negativo (aperto)
09 [PB/AT]-[ABPT]-[PAB/T]
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Shows 10 of 22
Column selection
Tipo
Bobina magnetica
Copertura
Tipo di pistone
Esecuzione
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]