Esecuzione
valvola a 4/2 vie o valvola a 4/3 vie
con azionamento manuale d'emergenza
Attacco
ISO/Cetop 03 NG 6
Portata
max. 80 l/min (si vedano le curve caratteristiche)
Please choose a variant
Article
HK 41 3151 0101 C1 R
HK 41 3151 0101 C1 Q
HK 41 3151 0101 C1 G
HK 41 3151 0101 C1 7
HK 41 3111 0101 C1 R
HK 41 3111 0101 C1 Q
HK 41 3111 0101 C1 G
HK 41 3111 0101 C1 7
HK 41 3151 0201 C1 R
HK 41 3151 0201 C1 Q
HK 41 3151 0201 C1 G
HK 41 3151 0201 C1 7
HK 41 3101 0601 C1 R
HK 41 3101 0601 C1 Q
HK 41 3101 0601 C1 G
HK 41 3101 0601 C1 7
HK 41 3103 0601 C1 R
HK 41 3103 0601 C1 Q
HK 41 3103 0601 C1 G
HK 41 3103 0601 C1 7
HK 41 3108 0601 C1 R
HK 41 3108 0601 C1 Q
HK 41 3108 0601 C1 G
HK 41 3108 0601 C1 7
HK 41 3107 0601 C1 R
HK 41 3107 0601 C1 Q
HK 41 3107 0601 C1 G
HK 41 3107 0601 C1 7
HK 41 3152 0101 C1 R
HK 41 3152 0101 C1 Q
HK 41 3152 0101 C1 G
HK 41 3152 0101 C1 7
HK 41 3201 0302 C1 R
HK 41 3201 0302 C1 Q
HK 41 3201 0302 C1 G
HK 41 3201 0302 C1 7
HK 41 3203 0302 C1 R
HK 41 3203 0302 C1 Q
HK 41 3203 0302 C1 G
HK 41 3203 0302 C1 7
HK 41 3208 0302 C1 R
HK 41 3208 0302 C1 Q
HK 41 3208 0302 C1 G
HK 41 3208 0302 C1 7
HK 41 3207 0302 C1 R
HK 41 3207 0302 C1 Q
HK 41 3207 0302 C1 G
HK 41 3207 0302 C1 7
HK 41 3751 0902 C1 R
HK 41 3751 0902 C1 Q
HK 41 3751 0902 C1 G
HK 41 3751 0902 C1 7
Register now to get access to our online shop
Register now and access our complete product range and many exclusive services.
Characteristics
Esecuzione
- valvola a 4/2 vie o valvola a 4/3 vie
- con azionamento manuale d'emergenza
Attacco
- ISO/Cetop 03 NG 6
Portata
- max. 80 l/min (si vedano le curve caratteristiche)
Pressione d'esercizio
- P, A, B: max. 350 bar / T: max. 210 bar (V DC) / T: max. 140 bar (V AC)
Elemento di fissaggio
- 4 pz. vite a testa esagonale interna M 5 x 30 12.9
Customs tariff number
- 84812010
All characteristics
Product description
Notes
Description
Ordering information
Delivery scope
Product variants
52 Results
Search
Show dimensional drawing
Identifier
Price / items
4/2
12 V DC
positive (closed)
51 [PB/AT]-[PA/BT]
4/2
24 V DC
positive (closed)
51 [PB/AT]-[PA/BT]
4/2
205 V DC
positive (closed)
51 [PB/AT]-[PA/BT]
4/2
230 V AC 50 Hz
positive (closed)
51 [PB/AT]-[PA/BT]
4/2
12 V DC
negative (open)
11 [PB/AT]-[PA/BT]
4/2
24 V DC
negative (open)
11 [PB/AT]-[PA/BT]
4/2
205 V DC
negative (open)
11 [PB/AT]-[PA/BT]
4/2
230 V AC 50 Hz
negative (open)
11 [PB/AT]-[PA/BT]
4/2
12 V DC
positive (closed)
51 [PB/AT]-[PA/BT]
4/2
24 V DC
positive (closed)
51 [PB/AT]-[PA/BT]
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]
Shows 10 of 52
Column selection
Type
Nominal voltage/ current type
Overlap
Piston type
Design
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]